Control System Design for 3 Storey Elevator Using PLC OPTA FINDER

Authors

  • Suparmono Politeknik Negeri Medan
  • Trahman Sitepu Politeknik Negeri Medan
  • Aulia Salman Politeknik Negeri Medan
  • Sutan Pardede Politeknik Negeri Medan
  • Cholish Politeknik Negeri Medan
  • Abdullah Politeknik Negeri Medan
  • Irfan Nofri CV Jiwa Karya

DOI:

https://doi.org/10.53893/ijrvocas.v4i4.384

Keywords:

Elevator Control System, PLC OPTA FINDER, Automation, Safety, Energy Efficiency

Abstract

Elevators are a crucial vertical transportation system in multi-story buildings, and the use of an appropriate control system can enhance operational efficiency, comfort, and safety. This study aims to design a control system for a 3-floor elevator using a Programmable Logic Controller (PLC) OPTA FINDER, which offers advantages in flexibility and ease of programming. The design process involved creating a control system schematic, programming with ladder diagrams, and testing on a small-scale elevator model. The test results demonstrated that the system could operate the elevator with fast and accurate response in detecting floor positions, controlling automatic doors, and responding to emergency conditions. Furthermore, the PLC OPTA FINDER proved reliable in managing elevator system components and facilitating program modifications without requiring hardware changes. This control system also contributes to energy efficiency through optimized motor speed regulation. Thus, the implementation of the PLC OPTA FINDER provides an effective and safe solution for modern elevator control systems.

References

M. M. Aslam, A. Tufail, R. A. A. H. M. Apong, L. C. De Silva, and M. T. Raza, “Scrutinizing Security in Industrial Control Systems: An Architectural Vulnerabilities and Communication Network Perspective,” IEEE Access, vol. 12, no. May, pp. 67537–67573, 2024, doi: 10.1109/ACCESS.2024.3394848.

Schneider-electric.com, “TM221CE16T - controller M221 16 IO transistor PNP Ethernet _ Schneider Electric,” se.com, 2019. .

Y. Jeong et al., “PLC and Arduino Interaction Based on Modbus Protocol,” J. Korea Multimed. Soc., vol. 20, no. 3, pp. 511–519, 2017, doi: 10.9717/kmms.2017.20.3.511.

B. S. Thinggaard et al., “The I-OPTA Questionnaire: A National Assessment of Patients with Neovascular Age-Related Macular Degeneration,” Ophthalmol. Ther., no. 0123456789, 2024, doi: 10.1007/s40123-024-01028-4.

J. B. Leth, “Fra vurdering til evaluering . Hvad skete der med forståelsen af livslang læring i vores optagelsessystem ?,” 2000.

D. I. Ingegneria, “Indice,” 2023.

D. S. Oleh, “Tugas Akhir Perancangan Simulator Lift 3 Lantai Menggunakan Smart Relay Zelio Sr2B201Bd Nim : Muhammad Listriawan Fakultas Teknik Jurusan Teknik Elektro,” 2012.

Additional Files

Published

2025-01-31

How to Cite

Suparmono, Sitepu, T., Salman, A., Pardede, S., Cholish, Abdullah, & Nofri, I. (2025). Control System Design for 3 Storey Elevator Using PLC OPTA FINDER. International Journal of Research in Vocational Studies (IJRVOCAS), 4(4), 73–78. https://doi.org/10.53893/ijrvocas.v4i4.384