Abstract

The electric panel has a function as a distribution device and as protection for electricity from the PLN. A panel must at least have protective equipment that functions so that if a fault occurs in electrical equipment, the fault can be corrected and does not interfere with the performance of the panel. In order for the protection equipment to work properly, accuracy is required in selecting the current rating and breaking capacity value of the protection components used. The purpose of this research is to analyze the breaking capacity value, nominal load current value, and short circuit current for each electrical protection component in the busbar room panel at PT Trias Indra Saputra. The analysis was carried out by comparing the results of manual calculations with calculations using the XL3-Pro calcul software, as well as the installed protection components. After calculating and comparing the results, the electrical protection components are still suitable for use as protection in the event of a fault, both short circuit fault and overcurrent on the electrical equipment in the busbar room panel at PT Trias Indra Saputra. In the outgoing protection Q0 is a protection component that connects the power source from the LVMDP panel to the busbar room panel at PT Trias Indra Saputra. Different results were obtained from the three comparisons. By using the MCCB current rating of 100A, it has been able to secure the circuit from short circuit faults and overload

Author Biographies

Herman Yani, Politeknik Negeri Sriwijaya

 

 

Nofiansah, Politeknik Negeri Sriwijaya

 

 

Monica Oktarani, Politeknik Negeri Sriwijaya

 

 

References

Abdullah Assegaf, Sunarto, Toto Tohir, (2019). Koordinasi Selektif MCB Metoda Waktu -Arus dengan Simulasi ETAP MCB Selective Coordination of Time Current Methods with ETAP Simulation. SENTER 2019, 23 - 24 November 2019, pp. 462-466 ISBN: 978-602-60581-1-9

Abrar Tanjung, Zulfahri, Hamzah, David Setiawan. (2018) Penerapan Sistem Proteksi Instalasi Listrik di Kecamatan Rumbai Pesisir, Fleksibel Jurnal

Agusthinus S. Sampeallo, Evtaleny R. Mauboy, Muhamad Iqbal, (2022), Analisis Fault Hubung Singkat Pada Panel Utama Tegangan Rendah Gardu C Bandara El Tari Kupang Untuk Menentukan Kapasitas Pemutusan Pemutus Tenaga Menggunakan Etap 12.6, Jurnal Media Elektro Vol. XI / No. 1 P-ISSN 2252-6692 | E-ISSN 2715-4963. 2022

Anton Firmansyah, Andika Pratama, D. ., & Ismail, M. R. . (2022). Influence of Maneuvering Singa Feeder at Bukit Siguntang Substation on Power Shrinkage Using ETAP 19.0.1. International Journal of Research in Vocational Studies (IJRVOCAS), 1(4), 16–21. https://doi.org/10.53893/ijrvocas.v1i4.70

Astanto, I. ., Arifin, F. ., Bow, Y. ., & Sirajuddin. (2022). Study of Effect Changing the Blade Shape and Lift Angles on Horizontal Wind Turbine. International Journal of Research in Vocational Studies (IJRVOCAS), 2(1), 33–37. https://doi.org/10.53893/ijrvocas.v2i1.92

Badan Standarisasi Nasional. (2000). Persyaratan Umum Instalasi Listrik 2000 (PUIL 2000), Jakarta: BSN

Badan Standarisasi Nasional. (2011). Persyaratan Umum Instalasi Listrik 2011 (PUIL 2011), Jakarta: BSN

Dimitrios Tzelepis, Adam Dyśko, Steven M. Blair, Anastasios Oulis Rousis, Sohrab Mirsaeidi, Campbell Booth, Xinzhou Dong, (2018). Centralised busbar differential and waveletbased line protection system for multiterminal direct current grids, with practical IEC-61869-compliant measurements. IET Journals ISSN 1751-8687

Efriyanti, R. ., Taqwa, A. . ., & Arifin, F. . . (2022). Temperature Decreasing Circulation of Solar Panels Using Water Flow. International Journal of Research in Vocational Studies (IJRVOCAS), 2(2), 48–52. https://doi.org/10.53893/ijrvocas.v2i2.106

Nurhabibah Naibaholo, Mohammad Yoverly, (2022). Analisis Perhitungan Kebutuhan Genset Stamford 670 KVA Pada Apartemen Mustika Golf Residence Cikarang Jawa Barat, Jurnal Elektro Vol 10 No 1 Januari 2022, ISSN : 2302-4712

Pratama, D. A. ., Anisah, M., & Setiyadi, K. A. . (2022). The Three Phase Induction Motor Test Using MATLAB 2021b/SIMULINK at Bukit Energi Servis Terpadu, Ltd. International Journal of Research in Vocational Studies (IJRVOCAS), 1(4), 60–65. https://doi.org/10.53893/ijrvocas.v1i4.84

Revy, S., Taqwa, A. . ., & Arifin, F. . . (2022). Utilization of Solar Energy in the Substation Energy in Provider Connected to PT. PLN (Persero) Based on IoT. International Journal of Research in Vocational

Additional Files

Published

2022-12-27

How to Cite

Yani, H., Aminah, N. ., Nofiansah, & Oktarani, M. . (2022). Analysis of Breaking Capacity Calculation on Busbar Room Panel at PT Trias Indra Saputra. International Journal of Research in Vocational Studies (IJRVOCAS), 2(3), 44–50. https://doi.org/10.53893/ijrvocas.v2i3.141